Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/25/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) CORRECTIONS MADE. GAS CARD AT METER |
| 02/24/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) PROVIDE FULL SIZE WATER HEATER VENT, DBL WALL THRU ROOF AREA TO APPROVED CAP 2) TEMPERATURE AND PRESSURE RELIEF SHALL BE 3/4" FULL SIZE APPROVED MATERIAL GRAVITY DRAIN TO DAY LIGHT 3) GAS PIPING AT WATER HEATER TO BE SECURED PROPERLY 4) PROVIDE PROPER BONDING FOR GAS PIPING |
| 02/23/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ PLEASE HAVE SOMEONE PRESENT TO PROVIDE ACCESS TO ENTIRE GAS SYSTEM. |