Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/01/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) CORRECTIONS MADE |
| 02/20/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) HAVE WTR HTR ADDED TO PERMIT AND INTERMEDIATE INSP. 2) SEWER TO HAVE AIR OR WTR TEST AT TIME OF INSP. 3) SEWER TO HAVE CLEAN OUTS AT CHANGE OF DIRECTION FOR OVER 135o (FULL SIZE 4"). 4) H2O PIPING IN CONTACT WITH EACH OTHER OR MASONARY TO BE SLEEVED OR 10 MIL. WRAPPED. 5) H2O AT WTR HTR AREA TO BE SUPPORTED IN VERTICAL. 6) VENT FROM WASHER HOOK UP TO BE SUPPORTED ON VERTICAL. OK TO INSULATE ALL EXTERIOR H20 PIPING. 7) H20 UNDER CONCRETE TO BE SILVER SOLDERED. 8) SECURE ALL H20 PROPERLY. |