Permit: T04PL00325

Parcel: 126181610

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/01/2004 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ 1) CORRECTIONS MADE
02/20/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) HAVE WTR HTR ADDED TO PERMIT AND INTERMEDIATE INSP. 2) SEWER TO HAVE AIR OR WTR TEST AT TIME OF INSP. 3) SEWER TO HAVE CLEAN OUTS AT CHANGE OF DIRECTION FOR OVER 135o (FULL SIZE 4"). 4) H2O PIPING IN CONTACT WITH EACH OTHER OR MASONARY TO BE SLEEVED OR 10 MIL. WRAPPED. 5) H2O AT WTR HTR AREA TO BE SUPPORTED IN VERTICAL. 6) VENT FROM WASHER HOOK UP TO BE SUPPORTED ON VERTICAL. OK TO INSULATE ALL EXTERIOR H20 PIPING. 7) H20 UNDER CONCRETE TO BE SILVER SOLDERED. 8) SECURE ALL H20 PROPERLY.