Permit: T04PL00289

Parcel: 130054380


Addresses:

2118 S TUCSON AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/08/2004 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ CORRECTION MADE. GAS CARD AT METER.
03/05/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 12 PSI PRESSURE TEST FROM METER NEW 3/4" STEEL TO WATER HEATER , 2 WALL HEATERS AND STOVE APPROVED. 1) BONDING TO BE INSTALLED CORRECTLY. 2) WALL HEATER VENT TO BE APPROVED MATERIAL AT ROOF PENETRATION WITH APPROVED CAP. 3) T&P FOR WTR HTR TO BE 6" TO 24" ABOVE FINISHED GRADE.
03/01/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) PROVIDE ROOF FLASHINGS AT PIPE PENETRATIONS THRU ROOF 2) PROVIDE APPROVED VENT AND CAP FOR FURNACE VENT. DOUBLE WALL FLU VENT PIPE OR CONNECT 3) SECURE PIPING 4) PROVIDE BONDING OF GAS PIPING. 2 CLIMPS (BRASS) #4 OR #6 COPPER WIRE 5) WATER HEATER TEMPERATURE AND PRESSURE RELIEF TO GRAVITY DRAIN TO DAY LIGHT. RETEST AND CALL BACK IN