Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/19/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) WTR HTR FLU VENT, T&P VALVE AND DRAIN IS OK. |
| 02/18/2004 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) MUST REMOVE THREAD PROTECTOR AND REPLACE WITH APPROVED COUPLING. 2) MUST INSTALL 5'0" OF DBL WALL FLU VENT WITH DBL WALL CAP. EXTEND THRU CEILING THEN CONNECT SINGLE WALL FLU VENT WITH THREE SHEET METAL SCREWS PER JOINT AND AT APPLIANCE COLLAR. 3) MUST EXTEND T&P DRAIN TO DAYLIGHT TERMINATE 6" A.F.F. 4) RE-TEST SYSTEM 10 LBS. |