Permit: T04PL00280

Parcel: 129131130


Addresses:

826 E 31ST ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/19/2004 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) WTR HTR FLU VENT, T&P VALVE AND DRAIN IS OK.
02/18/2004 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) MUST REMOVE THREAD PROTECTOR AND REPLACE WITH APPROVED COUPLING. 2) MUST INSTALL 5'0" OF DBL WALL FLU VENT WITH DBL WALL CAP. EXTEND THRU CEILING THEN CONNECT SINGLE WALL FLU VENT WITH THREE SHEET METAL SCREWS PER JOINT AND AT APPLIANCE COLLAR. 3) MUST EXTEND T&P DRAIN TO DAYLIGHT TERMINATE 6" A.F.F. 4) RE-TEST SYSTEM 10 LBS.