Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/17/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ CORRECTIONS MADE - GAS CARD BY MECH. INSPECTOR. |
| 02/11/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 10 PSI PRESSURE TEST FROM EXISTING METER 3/4" LINE TO WTR HTR, NEW ½" TO WTR HTR AND ½" TO ROOF TOP UNIT APPROVED. 1) PERMIT FOR NEW ROOFTOP UNIT REQUIRED. 2) ADD INTERMEDIATE INSPECTION FOR MOVING LOCATION OF WTR HTR AND NEW WTR HTR. PLUS ADDITION OF EXTERIOR HOT AND COLD HOSE BIBS. 3) PROVIDE PROPER BONDING OF GAS PIPING. 4) VERIFY MAX 3' ON GAS FLEX TO ROOFTOP UNIT. |