Permit: T04PL00256

Parcel: 132090430

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/17/2004 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES ARE OK. 3) WTR HTR FLU VENT, T&P VALVE AND DRAIN IS OK. 4) OK TO BACKFILL TRENCH.
02/13/2004 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) GAS GUAGE IS BELOW 10 LBS. 2) REMOVE UNION IN LINE AND REPLACE WITH RIGHT AND LEFT HAND NIPPLE. 3) MUST REPLACE T&P VALVE AND CONNECT FLU VENT FOR WATER HTR. 4) MUST PERM CAP FURNACE SUPPLY IF FURNACE IS NOT WORKING.