Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 02/18/2004 |
PLUMBING - GAS PRESSURE TEST |
|
Approved |
IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK. 2) WTR HTR FLU VENT, T&P VALVE AND DRAIN IS OK. 3) ALL CORRECTIONS HAVE BEEN MADE. |
| 02/13/2004 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999*/ 1) MUST RUN T&P DRAIN TO WTR HTR TO DAYLIGHT. YOU MAY USE CPVC, COPPER OR GALVANIZED PIPE. 2) MUST REMOVE UNION IN LINE AND USE RIGHT AND LEFT HAND NIPPLE OR LOCATE A GAS SHUT OFF BEFORE THE UNION AT HOUSE SUPPLY ONLY. 3) MUST SCREW DOWN FLU VENT FOR WTR HTR WITH [3] SHEET METAL SCREWS AT APPLIANCE COLLAR. 4) MUST PROVIDE 2 - 10X10 LOUVER GRILLS 12" ABOVE FLOOR AND 12" BELOW CEILING. |
| 02/10/2004 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999*/ 1) NEW GAS LINE TO WATER HTR GLAR. , PIPE IN DITCH COVERED. NEEDS TO BE SCOTCH COATED PIPE. WTR HTR B-1 VENT UP THRU ROOF, NEEDS TO HAVE 1" AROUND PIPE FROM WOOD. 2) PIPE FOR HT STOVE INCORRECT. |