Permit: T04PL00223

Parcel: 136062330


Addresses:

9008 E CALLE DIEGO


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T04PL00223

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
02/05/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*
02/04/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection 0000*/ 10 PSI PRESSURE TEST TO BE ON ENTIRE GAS PIPING SYSTEM AT TIME OF INSPECTION. 1) APPROVED AGA OR CSA GAS VALVES TO BE INSTALLED ON EACH APPLIANCE. 2) THREAD PROTECTORS ARE NOT APPROVED COUPLING FITTINGS. REPLACE AND RETEST ENTIRE SYSTEM. CALL BACK IN FOR INSP. 3) PROVIDE PROPER BONDING OF GAS PIPING.