Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T04PL00207
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/09/2004 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection 0000*/ 1) 14 PSI TEST IS OK 2) LEFT GAS CARD 3) INSPECTED GAS LINE TO 1 UNIT HEATER ONLY | |
02/06/2004 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection 0000*/ 1) REQUIRE MINIMUM 10 PSI TEST 2) INSTALL ALL VALVES, MAKE ALL CONNECTIONS. DO NOT TEST THROUGH THE APPLIANCE. CHECK ROOF TOP UNIT FOR GAS | |
02/04/2004 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection 0000* |