Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/04/2004 |
PLUMBING - FINAL |
|
Approved |
1) ALL CORRECTIONS HAVE BEEN MADE |
| 02/03/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) WTR HTR FLU VENT, T&P VALVE AND DRAIN IS OK. 4) EXISTING WALL FURNACE IS OK. |
| 02/02/2004 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) MUST REPLACE T&P VALVE AND PROVIDE DRAIN AND TERMINATE TO DAYLIGHT. 2) MUST PROVIDE A LICENSED PLBG CONTRACTOR TO DO ANY WORK ON GAS SYSTEM FOR RENTAL PROPERTY. 3) MUST PROVIDE 1" CLEARANCE AROUND DBL WALL FLU VENT FOR WTR HTR. 4) MUST PROVIDE [3] SHEET METAL SCREWS PER JOINT AND APPLIANCE COLLAR. 5) MUST USE TEST GAUGE WITH 1/10TH INCREMENTS AND ABOVE 10 LBS. MIN. |