Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T04PL00172
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/04/2004 | PLUMBING - FINAL | Approved | 1) ALL CORRECTIONS HAVE BEEN MADE | |
02/03/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) WTR HTR FLU VENT, T&P VALVE AND DRAIN IS OK. 4) EXISTING WALL FURNACE IS OK. | |
02/02/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*/ 1) MUST REPLACE T&P VALVE AND PROVIDE DRAIN AND TERMINATE TO DAYLIGHT. 2) MUST PROVIDE A LICENSED PLBG CONTRACTOR TO DO ANY WORK ON GAS SYSTEM FOR RENTAL PROPERTY. 3) MUST PROVIDE 1" CLEARANCE AROUND DBL WALL FLU VENT FOR WTR HTR. 4) MUST PROVIDE [3] SHEET METAL SCREWS PER JOINT AND APPLIANCE COLLAR. 5) MUST USE TEST GAUGE WITH 1/10TH INCREMENTS AND ABOVE 10 LBS. MIN. |