Permit: T04PL00142

Parcel: 132110290


Addresses:

2204 E 36TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/06/2004 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) WTR HTR FLU VENT T&P VALVE AND DRAIN IS OK.
02/04/2004 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) MUST PROVIDE AIR PRESSURE TEST ON ENTIRE SYSTEM - NEW LINE AND EXISTING - 10 LB MIN. 2) MUST PROVIDE A WTR HTR ENCLOSURE AND PROVIDE FLU VENT, T&P DRAIN AND FLU VENT, T&P DRAIN AND FLU VENT CAP MIN. 5'0" FROM APPLIANCE COLLAR AND SCREW DOWN FLU VENT JOINTS WITH [3] SHEET METAL SCREWS PER JOINT AND AT APPLIANCE COLLAR.