Permit: T04PL00124

Parcel: 10612056A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T04PL00124

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/10/2004 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ 1) GAS SHUT OFF VALVES ARE OK. 2) WTR HTR FLU VENT T&P VALVE AND DRAIN IS OK. 3) OK TO BACKFILL TRENCH.
02/09/2004 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) MUST PROVIDE AGA OR CSA GAS SHUT OFF VALVES AT ALL APPLIANCES. MUST ADD A NIPPLE ON DOWN SPOUT OF 90o FOR T&P DRAIN AND CUT OFF THREADS. 4) MUST SCREW DOWN WTR HTR FLU VENT WITH (3) SHEET METAL SCREWS PER JOINT AND AT APPLIANCE COLLAR.
02/03/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ T&P RELIEF DRAIN TO HAVE 90o TURN DOWN. IT MAY NOT HAVE A THREAD END. TERMINATION TO BE 6" AFF.