Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/10/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*/ 1) GAS SHUT OFF VALVES ARE OK. 2) WTR HTR FLU VENT T&P VALVE AND DRAIN IS OK. 3) OK TO BACKFILL TRENCH. | |
02/09/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*/ 1) MUST PROVIDE AGA OR CSA GAS SHUT OFF VALVES AT ALL APPLIANCES. MUST ADD A NIPPLE ON DOWN SPOUT OF 90o FOR T&P DRAIN AND CUT OFF THREADS. 4) MUST SCREW DOWN WTR HTR FLU VENT WITH (3) SHEET METAL SCREWS PER JOINT AND AT APPLIANCE COLLAR. | |
02/03/2004 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000*/ T&P RELIEF DRAIN TO HAVE 90o TURN DOWN. IT MAY NOT HAVE A THREAD END. TERMINATION TO BE 6" AFF. |