Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T04PL00124
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/29/2004 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection 0000*/ 1) OK TO COVER UNDERGROUND. PVC IS NOT APPROVED MATERIAL FOR T&P RELIEF DRAIN. 2) MAKE CORRECTION AND CALL FOR FINAL. | |
01/27/2004 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection 0999*/ 1) WATER HEATER TO SIT ON CONCRETE TASE, OR OTHER APPROVED MATERIALS 2) T & P RELIEF DRAIN TO BE FULL SIZE AND TERMINATE IN AN APPROVED MANNER 3) INADEQUATE COMBUSTION RELIEF IN SHED 4) ALL FITTINGS AND MARRED SECTIONS OF PIPE BELOW GRADE TO BE PIMED AND TAPED IN AN APPROVED MANNER | |
01/26/2004 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection 0000*/ PLEASE PROVIDE ACCESS TO STRUCTURE WITH SOMEONE HOME AT TIME OF INSPECTION. |