Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04PL00124

Parcel: 10612056A

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T04PL00124

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
01/29/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*/ 1) OK TO COVER UNDERGROUND. PVC IS NOT APPROVED MATERIAL FOR T&P RELIEF DRAIN. 2) MAKE CORRECTION AND CALL FOR FINAL.
01/27/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*/ 1) WATER HEATER TO SIT ON CONCRETE TASE, OR OTHER APPROVED MATERIALS 2) T & P RELIEF DRAIN TO BE FULL SIZE AND TERMINATE IN AN APPROVED MANNER 3) INADEQUATE COMBUSTION RELIEF IN SHED 4) ALL FITTINGS AND MARRED SECTIONS OF PIPE BELOW GRADE TO BE PIMED AND TAPED IN AN APPROVED MANNER
01/26/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection 0000*/ PLEASE PROVIDE ACCESS TO STRUCTURE WITH SOMEONE HOME AT TIME OF INSPECTION.