Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04PL00118

Parcel: 135081430


Addresses:

7208 E 28TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/30/2004 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ PETITION OF APPEAL NO. 2004-11 ON SITE. CORRECTIONS MADE.
01/26/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) TEMP AND PRESSURE RELIEF MUST GRAVITY DRAIN TO DAYLIGHT OR PROVIDE PROPER INSTALLATION WITH PETITION OF APPEAL ON SITE AT TIME OF INSPECTION. 2) VENT CONNECTION FOR WTR HTR MUST BE PROPERLY SECURED. 3) VENT FOR WTR HTR IF WITHIN 10' OF COOLER INTAKE TO BE 3' ABOVE WITH APPROVED GAP.