Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/22/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 10 PSI PRESSURE TEST APPROVED FROM METER TO WTR HTR AND FURNACE. CORRECTIONS MADE. |
| 01/20/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) UNION AT FURNACE SHALL BE LEFT AND RIGHT NIPPLE AND COUPLING OR BE PRECEEDED BY APPROVED VALVE IN ACCESSABLE LOCATION WITHIN 3' OF APPLIANCE. 2) VENTS FROM WATER HEATER AND FURNACE WITHIN 10' OF COOLER INTAKE TO BE 3' ABOVE COOLER. 3) GAS PIPING TO BE PROPERLY BONDED. 4) MAKE CORRECTIONS AND RETEST, CALL BACK FOR INSPECTION. |