Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/04/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ all corrections have been made. |
| 02/02/2004 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ SEE NOTES FROM PREVIOUS INSP. DATED 01/27/04 |
| 01/27/2004 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0339*/ 1) MUST PROVIDE (3) SHEET METAL SCREWS PER JOINT ON FLU VENT AND APPLIANCE COLLAR AT WATER HEATER 2) GAS BONDING MUST ATTACH TO HOUSE GAS LINE NOT S.W. GAS SUPPLY |
| 01/16/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) VENT FOR WALL HEATER TO BE EXTENDED 3' ABOVE COOLER IF WITHIN 10 FT OF COOLER INTAKE. 2) DRAFT HOOD ON WATER HTR TO BE CORRECTLY INSTALLED. 3) PROVIDE BONDING OF GAS PIPING. |