Permit: T04PL00071


Addresses:

1315 E BANTAM RD

Inspection Status: Approved

Inspection History: PLUMBING - PROGRESS

Date Description Inspector Results Comments
02/04/2004 PLUMBING - PROGRESS Approved IVRS - Inspection 0000*/ AIR PRESSURE TEST ON ENTIRE SITE SEWER SYSTEM IS OK.
01/26/2004 PLUMBING - PROGRESS Partial Approval IVRS - Inspection 0000*/ 1) SITE SEWER FROM M.H. 1 TO LOTS 1-11 AND 17-19 ONLY, AS NOTED ON PLAN. 2) OK TO BACKFILL TRENCH. 3) WILL REQUIRE A CERTIFIED SURVEYOR TO VERIFY GRADE AT EVERY 50' INTERVALS PRIOR TO BACKFILL. 4) WILL PROVIDE AN AIR PRESSURE TEST AT A LATTER TIME.
01/22/2004 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection 0000*/ NOT READY DUE TO RAIN.
01/20/2004 PLUMBING - PROGRESS Denied IVRS - Inspection 0999*/ CAN NOT USE SADDLE TAPS ON PRIVATE SEWER SYSTEM. MUST PROVIDE DIRECTIONAL FITTINGS.