Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/25/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) NO WTR TEST ON SYSTEM. 2) USE DRAINAGE FITTINGS NOT VENT FITTINGS AT WALL PENETRATIONS. REMOVE FURNEO COUPLINGS AND REPLACE WITH SOLVENT WELD FITTINGS. 3) ALL DRAINAGE PIPING TO HAVE 2% GRADE. 4) CONTRACTOR - OWNER IS AWARE THAT ABS MAY NOT BE USED IN EXPOSED EXTERIOR LOCATIONS, AND ASKED IF PAINTING IS OK. INSPECTION STOPPED. |
| 01/15/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ PROVIDE WATER TEST. REMOVE WATER PIPE FITTING. provide drainage fitting. |