Permit: T04PL00046

Parcel: 120090590

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
01/22/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) WTR HTR FLU VENT IS OK. T&P VALVE AND DRAIN IS OK. 4) MUST RE-INSTALL WALL FURNACE OR CAP OFF GAS SUPPLY.
01/21/2004 PLUMBING - GAS PRESSURE TEST Denied 1) MUST SCREW DOWN WATER HEATER FLU VENT WITH (3) SHEET METAL SCREWS PER JOINT 2) MUST REPLACE T & P VALVE FOR WATER HEATER 3) MUST HARD PIPE GAS LINE INTO WATER HEATER ENCLOSURE THEN CONNECT VALVE AND FLEX CONNECTOR 4) MUST PROVIDE ROOF FLASHING FOR ALL PENETRATIONS THRU ROOF 5) MUST PROVIDE TWO HOLE STRAPS FOR GAS LINE ON ROOF 6) RETEST SYSTEM