Inspection History Details
Inspection Status: Approved
Inspection History: SIGN ELECTRIC
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/20/2005 | SIGN ELECTRIC | Approved | IVRS - Inspection :* SIGN PERMITS 52468 52469 |
|
| 04/21/2005 | SIGN ELECTRIC | Partial Approval | IVRS - Inspection :* 1) TRANSFORMER ENCLOSURES NOT BONDED #6 2) USE LISTED APPROVED FITTINGS FOR CAR FLEX 3) #2 PREVIOUS INSPECTION |
|
| 04/08/2005 | SIGN ELECTRIC | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BOOT SPLICES NOT TO BE CUT-INSTALL AS PER MANUFACTURERS REQUIREMENTS.2) TIGHTEN LOOSE FITTINGS- INSTALL LOCKNUTS CORRECTLY. 3) SUPPORT FLEX ?? FLEX. 4) GROUND JUNCTIONS BOXES. 5) GTO TO MAINTAIN 1 1/2" CLEARANCES IN ENCLOSURE AND SHORT AS POSSIBLE WHILE KEEPING TO MIN LENGHTS. 6) BOND ENCLOUSER |