Inspection History Details
Inspection Status: Approved
Inspection History: SIGN ELECTRIC
Permit Number - T04OT02107
Inspection Description - SIGN ELECTRIC
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/09/2006 | SIGN ELECTRIC | Approved | IVRS - Inspection :* OK SIGNS 1. TIGHTEN LOOSE FITTINGS 2. TIGHTEN HIGH VOLTAGE CONNECTION. |
|
03/08/2006 | SIGN ELECTRIC | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR TO RESCHEDULE FOR ACCESS |
|
06/28/2005 | SIGN ELECTRIC | Partial Approval | IVRS - Inspection :* PLEASE FINISH #4 PREVIOUS INSPECTION | |
06/20/2005 | SIGN ELECTRIC | Not ready for Inspection | IVRS - Inspection :* 1) ISOLATE PRIMARY CONDUCTORS TO SWITCHES. 2) SWITCHES TO BE AS PER 600.6 OR LOCKABLE. 3) SUPPORT GTO UP OFF OF GROUNDED SURFACES AND MAINTAIN 1 1/2" SPACING. 4) PLEASE PROVIDE ACCESS TO TRANSFORMERS AND POWER SUPPLIES AS PER 600.21 2' X 3' OPENING AND ACCESS CATWALKS 1" WIDE. 5) MAINTAIN 1/4" GLASS CLEARANCE. |