Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04OT02093

Parcel: 131090060


Addresses:

5802 E 22ND ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/24/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
12/30/2004 PLUMBING - FINAL Not ready for Inspection COMPLETE ALL ITEMS
11/09/2004 PLUMBING - FINAL Denied PROVIDE CORRECT DRAINAGE FOR HAND SINK ON WEST WALL AND HAVE ADDED TO YOUR PLANS. PROVIDE 1" MINIMUM AIR GAP @ ALL FLOOR SINK INDIRECT DRAINS TERMINATION. PROVIDE CORRECT DRAINAGE FOR (3) COMPARTMENT SINK & ELBOWS FOR FLOW CONTROL. PROVIDE CORRECT DRAWING FOR SINK THAT IS SHOWN AS HAND SINK ON PLAN. PROVIDE CORRECT 5" MIN FOR VACUUM BREAKER CRITICAL LEVEL FOR URINAL IN MENS' REST ROOM. PROVIDE BACKFLOW PROTECTION FOR WATER @ DRINK DISPENSER. PROVIDE VACUUM BREAKERS FOR EXTERIOR HOSE BIBS. CORRECTLY SUPPORT GAS PIPING ON ROOF & @ MOTOR. CAP ANY UNUSED GAS VALVES. PROVIDE CORRECT CLEANOUT COVER @ GREASE TRAP ON EXTERIOR.