Permit: T04OT00929

Parcel: 129041820


Addresses:

2008 E BROADWAY BL

Inspection Status: Not ready for Inspection

Inspection History: SIGN ELECTRIC

Date Description Inspector Results Comments
06/17/2004 SIGN ELECTRIC Not ready for Inspection IVRS - Inspection :*/ 1) ACCESS TO BE AS PER 600-21. 2) THHN IS NOT AN APPROVED METHOD FOR SUPPORTING M/C CABLE. 3) NO CIRCUIT IS PROVIDED AS PER 600.5. 4) PROTECT CONDUCTOR THRU COMBUSTABLE WOOD AND AT ENTRANCE TO RACEWAY.
06/16/2004 SIGN ELECTRIC Partial Approval IVRS - Inspection :*/ OK NORTH SIGN CALL WHEN WEST SIGN READY.