Permit: T04OT00780

Parcel: 13313006K


Addresses:

7649 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: SIGN ELECTRIC

Date Description Inspector Results Comments
05/28/2004 SIGN ELECTRIC Approved IVRS - Inspection :*
05/27/2004 SIGN ELECTRIC Not ready for Inspection IVRS - Inspection :*/ BLDG LOCKED AND ACEES PANEL NOT ABLE TO OPEN.
05/12/2004 SIGN ELECTRIC Not ready for Inspection IVRS - Inspection :*/ 1) PLEASE PROVIDE ACCESS TO BALLAST AND POWER SUPPLIES AS PER CODE 600.21 (R) ACCESS IN BLDG IS AT LEAST 50+ FEET AWAY AND NOT ACCESSABLE AS PER 600.21 (E). 2) DISCONNECT SWITCH FOR NEW SIGN TO BE AS PER 600.6. A LOCKABLE DEVICE IS ALLOWED.