Permit: T04OT00749

Parcel: 11105009A

Inspection Status: Not ready for Inspection

Inspection History: SIGN ELECTRIC

Date Description Inspector Results Comments
08/02/2004 SIGN ELECTRIC Not ready for Inspection IVRS - Inspection :CANCELLED
07/01/2004 SIGN ELECTRIC Partial Approval IVRS - Inspection :*/ 1) SWITCH TO BE AS PER 600.6-A LOCKABLE DEVICE IS ALLOWED 2) SUPPORT M/C CABLE 3) INSTALL SIGN LABELS ON CORRECT SIGNS 4) WHERE IS MARKING LABEL PER 600.4