Inspection History Details
Inspection Status: Approved
Inspection History: SIGN ELECTRIC
Permit Number - T04OT00410
Inspection Description - SIGN ELECTRIC
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/13/2004 | SIGN ELECTRIC | Approved | IVRS - Inspection :* | |
| 07/29/2004 | SIGN ELECTRIC | Not ready for Inspection | IVRS - Inspection :1)use wire nuts as listed for number of conductors 2) TIGHTEN LOOSE FITTINGS & SEAL TITE HAS A LARGE CUT IN OUTER COVERING 3) SWITCHING FOR NEON TOBE AS PER 600-5 ALSO LED CONTROLS 4) PROPERLY SUPPORT LV CONDUCTORS FOR LED SIGNS AND SPLICES 5) PLEASE VERIFY IF A FIREWALL PENETRATION IS MADE 6) HOW IS LED SIGN ACCESSED? |