Inspection History: MECHANICAL - FINAL

Permit Number - T04ME00693

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/16/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
04/26/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
VENT CONNECTOR MUST BE INCREASED TO 4" AT OUTLET OR FURNACE. CONDENSATE VENT MUST BE DOWNSTREAM OF THE TRAP OR CAP OFF. DOUBLE WALL FITTINGS IN ATTIC UPSIDE DOWN. PIECE OF VENT PIPE BROKEN. EXTEND 2' ABOVE COOLER.
03/28/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. VERIFY COMBUSTION SUPPLY/RELIEF
2. PROPERLY PITCH FLUE
3. AIR RETURN MUST BE ISOLATED FROM GAS LINES, FURNACE COMPARTMENT, ETC.
4. SHUT-OFFS FOR GAS AND ELECTRIC DISCONNECTS MUST BE READILY ACCESSIBLE.
02/01/2005 MECHANICAL - FINAL Partial Approval IVRS - Inspection :* INSUFFICIENT CLEARANCE TO WOOD, DOOR CASING & DOOR, REFRIG. LINE ARMAFLEX INSUL, ETC. 1) RECOMMEND B-1 VENT DOWN TO FURN. 2) MUST MAINTAIN INCLINED PITCH UP TO TERMINATION. 3) CONCEAL CONTROL WIRING ON ROOF, EXPOSED TO SEEN. 4) CONN?? VERIFY COMBUSTION AIR VENT FROM CEILING OF FURN. RM.