Permit: T04ME00691

Parcel: 128061940


Addresses:

6093 E BEVERLY ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
12/02/2004 MECHANICAL - FINAL Approved IVRS - Inspection :*/20 PSI TEST IS OK. CORRECTIONS HAVE BEEN MADE.
11/04/2004 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)REMOVE THE GAS SHUT OFF VALVES FROM ALL WALL HEATERS & CAP OFF GAS LINES. PROVIDE A MIN. 10LB PRESSURE TEST ON ALL NEW GAS PIPING. 2)EXTEND CONDENSATE DRAIN TO WITHIN 6" OF THE GROUND & DIVERT THE WATER AWAY FROM THE HOUSE & THE FOUNDATION. 3)IDENTIFY THE CIRCUIT TO THE NEW A/C UNIT