Permit: T04ME00413

Parcel: 133220320

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
07/01/2004 MECHANICAL - FINAL Approved IVRS - Inspection :*/ ALL CORRECTIONS HAVE BEEN MADE.
06/24/2004 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) TIGHTEN ROMEX CONNECTORS ONTO CORD AT FURNACE. 2) PROVIDE A BUSHING TO PROTECT SUCTION LINE FROM SCRAPING ON COIL CABINET AND SEAL OPENING. 3) THE WTR HTR CANNOT BE REMOVED WITH THE REFRIGERATION LINES IN THE WAY. RELOCATE THE LINE SET UP AND OVER THE TOP OF THE WTR HTR. RECALL FOR INSP.