Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 04/20/2004 |
MECHANICAL - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) ALL CORRECTIONS HAVE BEEN MADE |
| 04/14/2004 |
MECHANICAL - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) CONDENSATE CANNOT DRAIN INTO A RAIN GUTTER THAT HAS NO DOWNSPOUT OR END CAPS GO TO WITHIN 6" OF THE GROUND. USE A ROOF JACK. 2) SEAL JOINTS ON DUCT WORK WITH DUCT SEALER NOT FOIL TAPE. SCREW FLASHING FOR RETURN DUCT TO ROOF BETTER. EDGES ARE COMING UP. ROOF NEEDS TO BE SEALED WHERE OLD COOLER LEGS LEFT INDENTATIONS IN ROOFING. SEAL DUCT CONNECTIONS TO UNIT WITH DUCT SEALER NOT FOIL TAPE. |