Permit: T04EL02491

Parcel: 133181000


Addresses:

6941 E 3RD ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/01/2005 ELECTRIC - FINAL Approved IVRS - Inspection :*
02/17/2005 ELECTRIC - FINAL Partial Approval IVRS - Inspection :* 1) J-BOX OVERFILLED SEE CI. ALLOWANCE @J-BOX # 12 IS 2.25 C.I. EACH ( APROX 20 # 12 CONDUCTORS) 2) BOX CONNECTIONS LOOSE AT BELL BOX 3/4" CONDUIT ENTERING 1" KO'S 3) GUTTER 3/4" OPENING IS NOT CLEAN & NO LONGER WEATHER PROOF. 4) CHANGE SQ ? BREAKER TO MURRAY-SIEMENS. 5) OTHER 1/2" BELL BOX IS LOOSE AS WELL ( SECURE 1/2" E.M.T)
02/11/2005 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) OK TO CLEAR