Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T04EL02480
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/11/2005 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
01/07/2005 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The service entrance is not per code.| 215* CORRECTIONS: 1) COLD WATER AND GAS PIPING MUST BE GROUNDED TO PANEL. 2) A (DURABLE) METALLIC ADDRESS MUST BE INSTALLED ABOVE OR BELOW METER SOCKET. 3) SIEMENS CIRCUIT BREAKERS CANNOT BE USED IN A CUTLER HAMMER. SEE PANEL TAG. 4) FASTENING HARDWARE TO MOUNT PANEL & RISER HARDWARE IS 1/4 " X ? BOLTS- LAYS - ECT. 5) THE GROUND WIRE MUST BE STRAPPED TO WALL WITH STRAPS MADE FOR THE PURPOSE. 6) MARK ALL YOUR CIRCUITS AT PANEL. THANKS , CORRECT & RECALL. |