Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T04EL02388
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/08/2005 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* NOTE: MOVE SMOKE DETECTOR IN S EAST BEDROOM A MIN. OR 3' AWAY FROM AIR REGISTER | |
12/06/2004 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) PER MINIMUM HOUSING STANDARDS INSTALL THE FOLLOWING PRIOR TO NEXT INSPECTION: WATER HEATER, KITCHEN SINK, STOVE, TOILET AND BATHROOM SINK 2) ALSO INSTALL IRC AND NEC: SMOKE DETECTOR IN HALLWAY 3) INSTALL LIGHT FIXUTRE IN BATHROOM WHERE IT IS CURRENTLY AN OPEN J-BOX 4) GROUNDING RECEPTACLES ARE NOT PERMITTED WITHOUT EITHER AN EQUIPMENT GROUNDING CONDUCTOR INSTALLED AS DESCRIBED IN ART 250 OF THE NEC OR THE MUST BE GROUND FAULT PROTECTED 5) OUTDOOR AND KITCHEN RECEPTACLES TO BE GFI PROTECTED 6) INSTALL WEATHER PROOF COVER AT FRONT WALK (PORCH) RECEPTACLE SEE 9 7) DBL CYLINDER DEAD BOLT IS NOT ACCEPTABLE AT DOORS (USE THUMB TURN ON INSIDE NOT KEY |