Permit: T04EL02388

Parcel: 126134610


Addresses:

4536 E DOUGLAS ST


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T04EL02388

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/08/2005 ELECTRIC - FINAL Approved IVRS - Inspection :* NOTE: MOVE SMOKE DETECTOR IN S EAST BEDROOM A MIN. OR 3' AWAY FROM AIR REGISTER
12/06/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) PER MINIMUM HOUSING STANDARDS INSTALL THE FOLLOWING PRIOR TO NEXT INSPECTION: WATER HEATER, KITCHEN SINK, STOVE, TOILET AND BATHROOM SINK
2) ALSO INSTALL IRC AND NEC: SMOKE DETECTOR IN HALLWAY
3) INSTALL LIGHT FIXUTRE IN BATHROOM WHERE IT IS CURRENTLY AN OPEN J-BOX
4) GROUNDING RECEPTACLES ARE NOT PERMITTED WITHOUT EITHER AN EQUIPMENT GROUNDING CONDUCTOR INSTALLED AS DESCRIBED IN ART 250 OF THE NEC OR THE MUST BE GROUND FAULT PROTECTED
5) OUTDOOR AND KITCHEN RECEPTACLES TO BE GFI PROTECTED
6) INSTALL WEATHER PROOF COVER AT FRONT WALK (PORCH) RECEPTACLE SEE 9
7) DBL CYLINDER DEAD BOLT IS NOT ACCEPTABLE AT DOORS (USE THUMB TURN ON INSIDE NOT KEY