Permit: T04EL01992

Parcel: 132110860


Addresses:

2432 E 36TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
12/14/2004 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
10/08/2004 ELECTRIC - RECONNECT Denied IVRS - Inspection :The wiring is not complete or does not comply with code.| RECEPTACLES IN FRONT PORCH MUST BE GFI TYPE WITH APPROVED WEATHERPROOF COVER
EXPOSED WIRING IN WATER HEATER RM NOT ALLOWED ROMEX WIRE BELOW 8' MUST BE PHYSICALLY PROTECTED
INSTALL SMOKE DETECTORS IN BEDROOMS, REPAIR LIGHT FIXTURES, CEILING FANS
NO COMPLIANCE WITH NOTES FROM LAST INSPECTION - A RE-FEE WILL BE ASSESED AT NEXT INSP IF NO COMPLIANCE
10/03/2004 ELECTRIC - RECONNECT Denied IVRS - Inspection :
There is no access to the site.| 920*
09/30/2004 ELECTRIC - RECONNECT Denied IVRS - Inspection :The wiring is not complete or does not comply with code.| REPAIR COVER TO SERVICE PANEL, ALSO FILL IN BLANK SPACES ON DEADFRONT
ELECTRICAL WIRING IN BACK STOREROOM NOT PER CODE. PROVIDE DOCUMENTATION FOR CARPORT & STOREROOM REFLECTING PERMITS OBTAINED FOR CONSTRUCTION & APPROVALS FOR INSPECTIONS
ALL WIRING OUTSIDE UNITS NOT APPROVED FOR OUTDOOR USE
RE-CALL INSP WHEN ACCESS AVAILABLE INSIDE UNIT
ALL WORK TO BE DONE BY C-11 LICENSED CONTRACTOR