Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
Permit Number - T04EL01633
Inspection Description - ELECTRIC - SERVICE UPGRADE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/16/2004 | ELECTRIC - SERVICE UPGRADE | Approved | IVRS - Inspection :* BE ADVISED, THE NEW SERVICE TO EXISTING SWITCH_ THE COLOR RED IS RESERVED FOR CURRENT CARRYING CONDUCTORS ( HOT) REPLACE WITH WHITE CONDUCTOR AND INCLUDE A GREEN CONDUCTOR TO GROUND THE STEEL OF THE SWITCH WITH THE STELLOF THE NEW PANEL. CHANGE PIPE OT 3/4 ". CALL FOR FINAL INSPECTION WHEN COMPLETE | |
08/13/2004 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : The service entrance is not per code.| 215* 1) YOUR GROUNDING CIRCUIT IS UNACCEPTABLE. THE ELECTRICAL CODE REQUIRES THE PRIMARY GROUNDING CONDUCTOR WIRE TO BE CONTINUOS AND UNBROKEN/SPLICED. THE SPLICE AT THE GOUND ROD NEAREST THE PANEL IS UNACCEPTABLE. THE COLD WATER AND GAS PIPES MUST BE BONDED( GROUNDED) THE ELECTRIC SERVICE AND A GROUND JUMPER INSTALLED FROM COLD WATER TO HOT WATER PIPES AT THE WATER HEATER.2) IDENTIFY THE CIRCUITS IN THE PANEL. WHAT AREAS OF THE HOUSE DO THEY SERVE? |
|
08/11/2004 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : The service is not per code.| 210*/CORRECTIONS NEEDED: 1)THE ADDRESS NUMBERS MUST BE PERMANENT. USE EMBOSSED METAL STRIP OR OTHER METALLIC, DURABLE, MEDIAL & MUST BE LOCATED ABOVE OR BELOW METER. 2)A COMPLETE NEW GROUNDING SYSTEM, IN COMPLIANCE WITH NEC ART. 250, MUST BE INSTALLED. LEAVE RODS EXPOSED FOR INSPECTION (ENDS W/CLAMP). RECALL. THANKS. |