Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/19/2005 | ELECTRIC - FINAL | Approved | IVRS - Inspection :*OK TO CLEAR | |
| 12/29/2004 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ALL GROUNDING TYPE RECEPTACLES MUST BE PROPERLY GROUNDED OR GFI PROTECTED OR REPLACE GROUNDING RECEPTACLES WITH NON-GROUNDING TYPE RECEPTACLES WHERE NO EQUIPMENT GROUNDING CONDUCTOR IS AVAILABLE 2) INSTALL SMOKE DETECTOR IN HALLWAY AND IN BEDROOMS (LOCATE MINIMUM 3' AWAY FROM AIR REGISTER AND 6"-12" FROM CEILING) |
|
| 08/23/2004 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/DENIED-NO ONE AT LIGHT. AREFEE? IS DUE PRIOR TO THE NEXT INSPECTION |
|
| 08/19/2004 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/DENIED-LOCKED-PLEASE RECALL |