Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/02/2004 | ELECTRIC - FINAL | Approved | OK TO CLEAR | |
| 08/11/2004 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :*/1)PLEASE FINISH #5 & #7 OF PREVIOUS INSPECTION | |
| 08/04/2004 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :CHASE NIPPLE NOT AN APPROVED FITTING FOR USE WITH L.B. A NEW GROUNDING ELECTRODE SYSTEM IS NEEDED FOR A SERVICE UPGRADE PLEASE VERIFY GAS AND WATER BONDING IS FOAM FILL NO COMBUSTIBLE ANF FLAME PROOF INSTALL ALL STRANDS UNDER TERMINAL LUGS LOCK NUT MISSTIN ON FITTING USE CORRECT SIZE BREAKERS FOR CONDUCTOR A PERMANENT METAL ADDRESS LABEL IS NEEDED |
|
| 08/02/2004 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :PLEASE LOCK-UP DOORS | |
| 07/29/2004 | ELECTRIC - FINAL | Denied | IVRS - Inspection :NO ANSWER AT DOOR, DOG IN YARD |