Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T04EL01389
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/13/2004 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 07/12/2004 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245*/ 1) OK GROUND RODS, WATER BOND, HOWEVER GAS BOND TO BE BONDED ON CUSTOMER SIDE OF GAS METER |
|
| 07/02/2004 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245*/ 1) NOTES: 2 GROUND RODS REQUIRED PER ART 250 NEC. ALSO NEED TO VERIFY GAS AND WATER PIPE BOND 2) COLOR CODING ON 120/240 WITH HIGH LEG, ORANGE CONDUCTOR TO BE ON "B" ? ON LOAD SIDE OF SERVICE, PER CITY OF TUCSON AMENDMENT 3) SPLICES ON GROUND ELECTRODE CONDUCTOR MUST BE IRREVERSIBLE TYPE, NO SPLIT BOLTS. RECALL WHEN READY |