Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T04EL01384
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/09/2004 | ELECTRIC - FINAL | Approved | ||
07/02/2004 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :*/ 1) EXTENTION CORDS TO BE 3 WIRE GROUNDED-MULTIPLE OUTLET STRIPS SHOULD ALSO BE USED 2) USE PROPER WIRING FOR FLY FAN/EXHAUST FAN OVER DOOR 3) OUTLET AT DISHWASHER TO HAVE WEATHER PROOF COVER WHEN PLUGED IN 4) FILL UNUSED OPENINGS IN PANEL, AT SWITCH COVER 5) MISSING OUTLET COVER PLATES 6) NEON SIGN TO BE SAFELY INSTALLED-YOU HAVE EXPOSED HIGH VOLTAGE CONNECTIONS 7) TERMINATE CONDUCTORS IN AN APPROVED BOX NOT JUST TAPED 8) CORRECTLY ADDRESS SERVICE 9) A LICENSED ELECTRICAL CONTRACTOR TO PERFORM WORK |