Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/09/2004 |
ELECTRIC - FINAL |
|
Approved |
|
| 07/02/2004 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) EXTENTION CORDS TO BE 3 WIRE GROUNDED-MULTIPLE OUTLET STRIPS SHOULD ALSO BE USED 2) USE PROPER WIRING FOR FLY FAN/EXHAUST FAN OVER DOOR 3) OUTLET AT DISHWASHER TO HAVE WEATHER PROOF COVER WHEN PLUGED IN 4) FILL UNUSED OPENINGS IN PANEL, AT SWITCH COVER 5) MISSING OUTLET COVER PLATES 6) NEON SIGN TO BE SAFELY INSTALLED-YOU HAVE EXPOSED HIGH VOLTAGE CONNECTIONS 7) TERMINATE CONDUCTORS IN AN APPROVED BOX NOT JUST TAPED 8) CORRECTLY ADDRESS SERVICE 9) A LICENSED ELECTRICAL CONTRACTOR TO PERFORM WORK |