Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE RELOCATION

Date Description Inspector Results Comments
07/15/2004 ELECTRIC - SERVICE RELOCATION Approved IVRS - Inspection :*
07/08/2004 ELECTRIC - SERVICE RELOCATION Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*/ 1) CHASE NIPPLES NOT ALLOWED, USE CLOSE NIPPLES WITH LOCKNUTS 2) USE APPROVED WIRE NUTS TO SPLICE GROUND WIRES IN J-BOX, TWISTING WIRES TOGETHER ONLY NOT APPROVED METHOD 3) USE PERMANENT ADDRESS LABEL ON SERVICE, NO MAGIC MARKER 4) GROUND J-BOX, DO NOT USE SHEET METAL SCREW 5) METHOD OF SUPPORTING RISER NOT APPROVED, SUPPORT STRAPS MUST BE SECURED TO STRUCTURE