Permit: T04EL01302

Parcel: 12511033A

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T04EL01302

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
09/17/2004 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :* APPROVED AS PER PREVIOUS INSPECTION
06/24/2004 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*/ 1) LABEL BREAKERS AT SUB PANEL. 2) A MAIN BREAKER IS NEEDED INSIDE PANEL AS A 2ND STRUCTURE. 3) BOND GROUNDING ELECTRODE CONDUCTOR TO CONDUIT PER CODE. 4) ALSO NEED GROUNDING ELECTRODE SYSTEM AT 2ND STRUCTURE. 5) MULTIWIRE CIRCUIT ON SAME YOKE TO HAVE MANUFACTURERS TIE HANDLE. OK TO BACKFILL AND COVER TRENCH.