Permit: T04EL01127

Parcel: 112051280

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T04EL01127

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/01/2004 ELECTRIC - FINAL Approved IVRS - Inspection :*
06/29/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ FRONT HOUSE - BATH - LIGHT NOT INSTALLED. / SERVICE AND REAR HOUSE - 1) PERMANENTLY LABEL SERVICE. 2) NEED KNOCKOUT SIDE BOTTOM OF SERVICE. 3) RODS TO BE 6' APART. 4) GROUND WIRES NOT TERMINATED ON RODS. 5) GROUND WIRE AT POLE MUST BE ATTACHED TO POLE ALL THE WAY DOWN THEN UNDERGROUND TO ROD. 6) MULTIPLE CONDUCTORS IN ACORN CLAMP. 7) REAR HOUSE NEEDS TO HAVE A FINAL APPROVAL FROM MINIMUM HOUSING INSP.
06/18/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
06/15/2004 ELECTRIC - FINAL Cancelled IVRS - Ri canceled
05/28/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) LIVING ROOM - BROKEN RECEPTS. 2) ALL COVERS FOR LIGHTS AND RECEPTS TO BE ON. 3) SMOKE DETECTORS REQUIRED IN ALL BEDROOMS. 4) INSTALL A GFI RECEPT BY KIT. SINK. 5) REPLACE RANGE OUTLET AND TAPE CONDUCTORS. 6) PERM. LABEL SERVICE - NO MARKER OR PEN. 7) SERVICE REQUIRES 2 GROUND RODS AND A GAS AND WTR BOND TO BOTH UNITS, SEAL HOLE BOTTOM OF SERVICE. 8) STRAP AND SUPPORT PVC AT BOTTOM OF SERVICE. 9) EXTERIOR WIRING AT REAR UNIT INCORRECT, NON-WEATHERPROOF WIRING, J-BOX TOO SMALL. 10) REAR UNIT WIRING INADEQUATE - MUST BE REDONE. 11) 30 AMP DISCONNECT OUTSIDE - SEAL HOLES. 12) MAIN PANEL AT FRONT HOUSE TO BE REGROUNDED TWO RODS WTR AND GAS BOND. 13) SUGGEST ALL 2 WIRE OUTLETS IN HOUSE BE CHANGED OUT. 14) YOU SHOULD OBTAIN THE SERVICES OF A LICENSED ELECTRICAL CONTRACTOR TO REDO ALL PROBLEMS ABOVE AND RECALL.