Permit: T04EL00964

Parcel: 13347433A

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T04EL00964

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/02/2004 ELECTRIC - FINAL Approved IVRS - Inspection :*/ 1) OK TO CLEAR ECO
05/26/2004 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*/ CHASE NIPPLE NOT AN APPROVED FITTING - USE AN APPROVED FITTING.
05/19/2004 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*/ 1) A PERMANENT METAL ADDRESS LABEL IS NEEDED. 2) PLEASE VERIFY 2ND GROUND ROD. 3) A BONDING DEVICE IS NEEDED FOR RISE. 4) UNDERGROUND CONDUITS COVERED WITHOUT INSPECTION - PLEASE UNCOVER. 5) INSTALL OVERCURRENT DEVICE AND TERMINATE CONDUCTOR. LABEL PANEL AFTER INSTALLATION