Permit: T04EL00894

Parcel: 132102950


Addresses:

2017 E JASON VISTA

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/28/2004 ELECTRIC - FINAL Approved IVRS - Inspection :* OK TO CLEAR INC NO ANSWER AT DOOR
10/01/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
NO INSPECTION NO CONTACT. NOTE:UPON CALLING UTR ELECTRIC TO ASK QUESTION THEIR NUMBER NO LONGER IN SERVICE. WILL LEAVE MESSAGE ON IVR SYSTEM STATING THAT INSPECTOR WILL NEED CONTRACTOR TEL. NUMBER, LICENSE NUMBER AND NAME.
09/23/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
09/22/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
There is no access to the site.| 920*
05/07/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245* 1. SUPPORT RISER ABOVE PANEL. 2. STRAP #4 BARE TO WALL AT WATER BOND.. 3. USE SEALING LOCKNUT FOR 1/2" CONDUIT CONNECTOR AT TOP ENTRY. 4. INSTALL CONNECTOR W/BUSHING TO PROTECT CABLE FROM ABRAISION WHERE CABLE EXISTS CONDUIT SLEEVE. 5. ROMEX MUST BE PROTECTED BELOW 8' AT OUTSIDE SWITCH. 6. SUPPORT 1/2" CONDUIT WITHIN 3' OF DRYER RECEPT.. 7. UPGRADE WILL NOT BE APPROVED UNTIL EXPOSED ROMEX WIRING AT BACK PORCH AND FRONT RECPT BY WATER CONDITIONER BROUGHT UP TO CODE. (UNSAFE)