Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/12/2004 | ELECTRIC - SERVICE UPGRADE | Approved | IVRS - Inspection :* | |
| 05/10/2004 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245*/ 1) WATER AND PIPING MUST BE BONDED TO NEW SERVICE PER 250.104 NEC. 2) OK TO USE EXISTING GROUND ROD, BUT IT MUST ALSO BE TIED INTO NEW SERVICE |
|
| 05/03/2004 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245*/ 1) BOND WATER AND GAS PIPING 2) INSTALL PERMANENT ADDRESS LABEL ON ENCLOSURE 3) USE 1/4 MINIMUM BOLTS TO SUPPORT RISER 4) SUPPORT BOX FOR GFI RECEPT |