Permit: T04EL00825

Parcel: 127080430


Addresses:

5425 E HOLMES ST

Inspection Status: Partial Approval

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
05/28/2004 ELECTRIC - SERVICE UPGRADE Partial Approval IVRS - Inspection :*/ 1) OK TO CLEAR 2) PLEASE RECALL AFTER CROSS OVER
05/21/2004 ELECTRIC - SERVICE UPGRADE Not ready for Inspection IVRS - Inspection :*
05/18/2004 ELECTRIC - SERVICE UPGRADE Partial Approval IVRS - Inspection :*/ 1) NO CONDUCTORS TO PASS THROUGH TOP END WALL PER MANUFACTURERS LABEL. 2) #8 ROMEX TO BE PROTECTED BY OVER CURRENT DEVICE AS PER 334-26 - 40 AMP MAX. 3) INTERIOR OLD PANEL NOT LISTED AS JUCTION BOX. 4) PLEASE VERIFY PERMIT FOR NEW A/C INSTALLATION