Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/04/2004 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 04/29/2004 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/27/2004 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The bonding is not per code.| 235*/ 1) THE ADDRESS ON THE PANEL IS NOT ON. MUST BE EMBOSSED METAL STRIP. 2) THE GROUND WIRE MUST BE A CONTINUOUS LENGTH, WITHOUT CUTS, ONE PIECE, FROM PANEL TO GROUND RODS. 3) DO NOT USE PENCIL, PEN, MAGIC MARKER OR ANY OTHER NON-METAL ITEM TO APPLY ADDRESS TO PANEL. |
|
| 04/26/2004 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The service is not per code.| 210*/ 1) THE GROUNDING IS NOT PER CODE. SEE TYPICAL DIAGRAM ON PAPER COPY. 2) THE MAIN PANEL NEEDS A METAL ADDRESS TAG ABOVE OR BELOW METER BASE. 3) THE GROUND WIRE AT THE ROD CLAMP MUST BE PLACED IN THE POCKET OPPOSITE THE BOLT. - DRIVE RODS 2" BELOW GROUND LEVEL. LEAVE EXPOSED FOR INSP. GROUND THE WIRE TO EACH ROD AND CONTINUE RUN OF WIRE TO COLD WTR AND GAS PIPES AT WTR HTR. |