Permit: T04EL00529

Parcel: 121040550

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
04/16/2004 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
04/07/2004 ELECTRIC - FINAL Denied IVRS - Inspection 0999*/ 1) FINISH #1 AND 2 OF PREVIOUS INSPECTION-A REFEE MAY BE ASSESSED IF NO WORK PROGRESS
04/01/2004 ELECTRIC - FINAL Denied IVRS - Inspection 0245*/ 1) NOTES: ISOLATE NEUTRAL AND GROUNDS AT SUB-PANEL. NEUTRAL IS BONDED AT MAIN SERVICE, TIE GROUNDS INTO GROUND BAR WITH EQUIPMENT GROOUND RUN WITH FEEDERS TO SUB-PANEL 2) GROUND RODS SHOULD BE CLOSER TO THE SERVICE, NOT ON THE OTHER SIDE OF THE HOUSE. THE #4 RUNS UNDER THE ROOF OVERHANGE COULD CAUSE DAMAGE IN THE EVENT OF POWER SURGE TO GROUND OR LIGHTING STRIKE. SEE 250-30 A3 NEC 99'