Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04EL00471

Parcel: 117160080


Addresses:

191 E TOOLE AV


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T04EL00471

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/19/2004 ELECTRIC - FINAL Approved IVRS - Inspection 0000*/ 1) WAS FINALED FOR ELECTRICAL
03/12/2004 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*/ 1ST INSP. 9 AM - LOCKED. 2:45 PM. - ELECTRICAL REPAIRS APPROVED FOR TEMP C OF O.
03/08/2004 ELECTRIC - FINAL Denied IVRS - Inspection 0999*/ 1ST INSP. 9:20 AM - LOCKED - WAS HERE TO MAKE A FOLLOW UP INSPECTION ON ELECTRICAL REPAIRS, PLEASE CALL 909-5184 TO SET UP AN INSPECTION ON REPAIRS. / 2ND INSPECTION - 12:00. 1) THE UFER IS TO BE ATTACHED TO THE NEUTRAL DIRECTLY. 2) NO ADDRESS LABEL ON SERVICE. 3) 50 ACB ON #12 WIRE. 4) OPEN WIRING SOUTH WALL ENTRY, PUT SPLICES IN BOXES. 5) COOLER WIRING IN CONDUIT, BLANK OF SW. IN STORAGE ROOM BY BATHROOM. 6) CORRECT ZIP CORD USE ON TRAC LIGHT NOT PERMITTED. 7) REMOVE ZIP CORD ON LIGHTS BY REAR DOOR.