Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/19/2004 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) WAS FINALED FOR ELECTRICAL |
| 03/12/2004 |
ELECTRIC - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1ST INSP. 9 AM - LOCKED. 2:45 PM. - ELECTRICAL REPAIRS APPROVED FOR TEMP C OF O. |
| 03/08/2004 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1ST INSP. 9:20 AM - LOCKED - WAS HERE TO MAKE A FOLLOW UP INSPECTION ON ELECTRICAL REPAIRS, PLEASE CALL 909-5184 TO SET UP AN INSPECTION ON REPAIRS. / 2ND INSPECTION - 12:00. 1) THE UFER IS TO BE ATTACHED TO THE NEUTRAL DIRECTLY. 2) NO ADDRESS LABEL ON SERVICE. 3) 50 ACB ON #12 WIRE. 4) OPEN WIRING SOUTH WALL ENTRY, PUT SPLICES IN BOXES. 5) COOLER WIRING IN CONDUIT, BLANK OF SW. IN STORAGE ROOM BY BATHROOM. 6) CORRECT ZIP CORD USE ON TRAC LIGHT NOT PERMITTED. 7) REMOVE ZIP CORD ON LIGHTS BY REAR DOOR. |