Inspection Status: Approved
Inspection History: ELECTRIC - UNDERGROUND
| Date |
Description |
Inspector |
Results |
Comments |
| 03/19/2004 |
ELECTRIC - UNDERGROUND |
|
Approved |
IVRS - Inspection 0000* |
| 03/18/2004 |
ELECTRIC - UNDERGROUND |
|
Denied |
IVRS - Inspection 0999*/ 1) UPGRADED SERVICES REQUIRE A NEW GROUNDING SYSTEM-2 GROUND RODS PLUS A WATER AND GAS LINE BOND 2) SERVICE REQUIRES A PERMANENT ADDRESS LABEL 3) CHASE NIPPLE CANNOT BE USED FOR ENTRY TO PANEL FROM LB FILTERING (USE CLOSED NIPPLE) 4) CAN ONLY USE MURRAY TYPE CIRCUIT BREAKERS 5) THE 1 1/4" CONDUIT OUTSIDE PANEL NEEDS TO BE SUPPORTED 6) NEUTRAL USES AS HOT ON A/C UNIT TO BE TAPED BLOCK 7) DOORS LOCKED UNABLE TO LOOK INSIDE TO SEE NEW WIRING TERMINATION FROM PANEL FEEDERS |
| 03/12/2004 |
ELECTRIC - UNDERGROUND |
|
Denied |
IVRS - Inspection 0999* |